S7-1200 and S7-1500 are two families of Siemens SIMATIC controllers programmed in the same TIA Portal environment but intended for machines of a different scale. The manufacturer calls the S7-1200 a Basic Controller and the S7-1500 an Advanced Controller. The choice depends on the number of signals and axes, safety requirements, line availability, the customer’s standard and how much the machine will grow after the first commissioning.
What is the difference between S7-1200 and S7-1500 in practice?
The S7-1200 controls a machine with a limited number of signals and axes, while the S7-1500 handles entire lines, advanced motion and installations that cannot be allowed to stop. The difference is not just processor speed. It is about scale: how many modules can be added, how many devices the network can serve, how much program fits in memory and which technology functions are available at all.
The comparison covers the current S7-1200 G2 generation, which Siemens recommends for new projects, and the standard S7-1500 CPUs.
| Criterion | S7-1200 G2 | S7-1500 |
|---|---|---|
| Place in the Siemens range | basic controller: single machines, simple lines | advanced controller: lines, work cells, process installations |
| Program / data memory | 150-300 KB / 500-750 KB | from 150 KB / 1 MB (CPU 1511) up to several MB of program and several dozen MB of data |
| Bit operation time | 37 ns | from several dozen ns in basic CPUs down to a few ns in the most powerful ones |
| Local expansion | up to 10 signal and communication modules (CPU 1214C) | up to 32 modules in the central rack + ET 200 islands on the network |
| PROFINET | 2 ports, IRT, up to 31 devices | up to 3 interfaces in larger CPUs, hundreds of devices |
| Motion | typically 4, max. 10 positioning axes, simple kinematics | more axes, synchronisation, cams; S7-1500T with kinematics and synchronisation between controllers |
| Languages | LAD, FBD, SCL | LAD, FBD, SCL, STL, GRAPH |
| Redundancy | none | S7-1500R and S7-1500H versions |
In TIA Portal both families share editors, the tag database and technology objects. The S7-1200 needs only a STEP 7 Basic licence, while the S7-1500 requires STEP 7 Professional, which matters for an OEM that hands the project over to the customer’s maintenance team.
When is the S7-1200 enough for a machine?
The S7-1200 is enough for a stand-alone machine whose inputs and outputs fit in a few expansion modules and whose motion is limited to a few axes. This is the typical range for packaging machines, labelling machines, dosing units, conveyors and simple assembly stations.
The generation change moved the limit up considerably. The first-generation S7-1200 handled motion at the level of single axes, while the S7-1200 G2 offers technology objects for synchronous axes, cams and simple kinematics, PROFINET IRT with a cycle synchronised with the program, and functional safety configured in STEP 7 Basic without a separate safety licence. A machine that a few years ago required an S7-1500 just because of a couple of synchronised axes will often fit in a G2 today.
Take an example from the shop floor: a simple packaging machine with vision inspection and three servo drives. An S7-1200 G2 can handle its logic, two positioning axes, one synchronous axis, communication with the camera over PROFINET and an HMI panel. A cheaper controller lowers the cost of every machine sold, which matters more in series production at an OEM than on a single line.
An interesting feature of the G2 is the NFC tag built into the CPU. A technician holds a phone against the housing and reads the device type, firmware version, IP address and diagnostic data, and the basic information is available even when the controller is not powered.
You can read more about how we work with this family on the page about Siemens S7-1200 PLC programming.
When does a machine need an S7-1500 instead of an S7-1200?
The S7-1500 is needed when the machine exceeds the resources of the S7-1200 or when the customer requires functions the S7-1200 does not have. Most often one of the following conditions decides:
- line scale: several hundred signals, many stations on the PROFINET network, several ET 200SP islands and HMI panels in one project;
- motion: more axes than a few positioning ones, synchronisation of many axes, Cartesian robots with conveyor tracking (S7-1500T);
- availability: a line that cannot stop after a CPU failure requires a redundant S7-1500R or S7-1500H controller, in which the standby CPU takes over control within up to 300 ms (R) or up to 50 ms (H);
- customer standard: corporate standards such as VASS, Daimler Integra or BMW TMO build their libraries on a specific hardware platform, so the controller follows from the specification rather than from the designer’s decision;
- languages and libraries: STL code carried over from older controllers or sequences in GRAPH require an S7-1500.
The risk appears when an S7-1200 is chosen “just enough”. The machine passes acceptance, and a year later the customer adds an inspection station, a code reader and another axis. Then memory and module slots run out, and moving to a larger controller means new hardware in the cabinet, a rebuilt network configuration and repeated testing. The cost of replacing a CPU in a running machine, with downtime and a new acceptance, is many times higher than the difference in controller price at the design stage.
For example, we programmed the production line of the eATS2.0 engine for Daimler on the S7-1500. You can read more about working with this family on the page about Siemens S7-1500 PLC programming.
Looking for an experienced Siemens S7 integrator? Get in touch and we will select an S7-1200 or S7-1500 and commission your machine.
How does the S7-1200 G2 change the choice between the S7-1200 and the S7-1500?
The S7-1200 G2 takes over some of the machines for which the smallest S7-1500 CPU used to be chosen. This mainly concerns designs with a few axes, a PROFINET IRT network and safety functions.
Siemens has announced a gradual phase-out of the first-generation S7-1200. Spare parts for G1 are to remain available for years to come, and current dates are given on the Siemens migration page. For the designer this means two things:
- a new machine on the S7-1200 should be built on G2 from the start, because G1 shortens the period in which the customer can buy a replacement without a redesign;
- a fleet of G1 machines does not need urgent replacement, but it is worth preparing a migration plan to G2 or S7-1500 at the next modernisation.
The boundary between the families has not disappeared. According to the Siemens division, the S7-1200 G2 handles basic motion, the S7-1500 a medium range and the S7-1500T the most demanding tasks. Redundancy, STL and GRAPH, and large programs remain on the S7-1500 side.
S7-1200 or S7-1500 – how to decide in a machine project?
The decision is made on the basis of a list of requirements, not the CPU price alone. Before choosing a controller it is worth having answers to five questions:
- How many input and output signals does the machine have today and how many may it have after expansion?
- How many axes need positioning, and how many need synchronisation or kinematics?
- Which safety functions are needed and should they run in the same CPU?
- Does the customer have its own programming standard or a list of approved controllers?
- Is downtime after a CPU failure acceptable, or does the line need redundancy?
If the answers fit within the resources of the S7-1200 G2 with room to spare, the machine will be cheaper and fit in a smaller cabinet. If even one requirement touches the limit, the S7-1500 is the safer choice. A reserve of memory and modules planned at the design stage helps avoid replacing the controller during operation.
Both controllers are programmed in the same basic languages, so logic written in LAD or SCL carries over between the families. The languages are covered in more detail in the post What are the PLC programming languages?, and manufacturers are compared in the article Leading PLC Manufacturers: A Guide for Manufacturing Companies.
Moving machines to newer Siemens controllers? As an integrator, we will migrate the program to an S7-1200 G2 or S7-1500.
FAQ
Sources
- Siemens, “SIMATIC S7-1200 G2 Deep Dive Launch Webinar” (data for the CPU 1212C and 1214C G2, motion, safety, NFC).
- Siemens, “SIMATIC S7-1200 – end of lifecycle for the first generation and the recommended solution for the future”: https://www.siemens.com/en-gb/products/migration-of-automation-systems/
- Siemens, “SIMATIC S7-1500 R/H” brochure (memory, performance, switchover times of redundant CPUs).
- Siemens, data sheet of the CPU 1511-1 PN (6ES7511-1AK02-0AB0).